ระบบควบคุมค่าคาร์บอนภายในเตาชุบแข็งแบบเติมคาร์บอน

 

     
 มิเตอร์ควบคุมค่าเปอร์เซ็นคาร์บอน ตู้ควบคุมโปรบ คาร์บอนโปรบ

Main Technical Specification

1.  Working environment
Atmosphere Pressure: 680~800 mm Hg 
Temperature: 0~40 ℃
Relative Humidity: <80%(40 ℃)
Vibration frequency: <25 Hz, amplitude <0.1 mm
No caustic gas in the air around
2.  Power Supply
Voltage range: 180~260 V AC
Frequency range: 47~63 Hz
3.  Applicable types of furnace atmosphere:
Dripping type atmosphere
Endo-thermic type atmosphere
Nitrogen-based (nitrogen-methanol) type atmosphere
In-site type atmosphere (air plus kerosene, acetone ,methane, propane or butane)
Details are in the following table: table1                                                                                                                           

Type

Atmosphere characteristic

0

Dripping type atmosphere. The output of enriching liquid and carrier liquid is controlled by pulse dripping.

1

Dripping type atmosphere. The output of enriching liquid is controlled by time proportion switching. The output of carrier liquid is controlled by on/off.

2

Endothermic type atmosphere. The output of enriching gas is controlled by valve position. The output of carrier gas is controlled by on/off.

3

Endothermic type atmosphere. The output of enriching gas is controlled by time proportion switching. The output of carrier gas is controlled by on/off.

4

‘Air adding kerosene’ type atmosphere. The output of kerosene is controlled by time proportion switching. The output of air is controlled by on/off.

5

‘Air adding kerosene’ type atmosphere. The output of kerosene is controlled by pulse dripping. The output of air is controlled by on/off.

6

Air adding acetone (or methane, propane, butane) types atmosphere. The output of enriching gas is controlled by on/off valve position. The output of air is controlled by valve positionon/off.

7

Air adding acetone (or methane, propane, butane) types atmosphere. The output of enriching gas is controlled by on/off. The output of air is controlled by time proportion switching.

  Note:  Type 4-7 needs special order.
Route numbers of controllable medium: 3 routes. (Carrier gas, enriching liquid/gas and diluting medium)
4. Carbon Potential Sensor
Oxygen probe (0~1250mV). The inner resistance of oxygen probe can be displayed by online inspection automatically.
5. Type Of Thermocouple
S,K. It can be selected by DIP switch.
6. Simulation Transfer Of Carbon Potential Record
1~5 V or 0~5 V , corresponding to 0.0~2.00 % C
7. Working mode
There are three working modes: constant carbon potential automatic control, program running automatic control,
and manual control.
Those two automatic control working modes need carbon potential sensor.
100 programs can be stored in HT9841. Each program can include 6 segments.
8. Control Method
The carbon potential can be controlled by pulse frequency or time proportion of solenoid valve in PID adjustment,
 or valve position of motor valve in PID adjustment.
9. Precision Of Automatic Control Of Carbon Potential
± 0.05 % C
10.Model And Number Of Slave Temperature Controller
Model: Japan, SR93
Number: 5 max
11.Protect for the Power Failure
Recover after the power failure, the interrupted program can be automatically continued.
12.Alarms for unloading or carbon potential over limit
13.Exterior Dimension  96×96×165 ( Height×Width×Depth Mm)
Panel Cutout   H92×W92 (Mm)

Type 0 atmosphere: Dripping type atmosphere. The output of enriching liquid and carrier liquid is controlled
by pulse dripping.

 